Tiếng Việt|English
Hotline: +84 89 88 99 578
{关键字}
Home > Lightning protection > AC Surge Protectors > AC Power Surge Protector Panels

Các game casino-Casino có bịp không

AC boxes surge protectors are devices for low voltage electrical installations 230/400V or 120/208V (Single or Three Phase). SPDs Type 1,2 or 3 for effective protection of sensitive equipment, in addition to the surge protector installation (coordination surge protector). Robust connectors, suitable for all type of connection.

Các game casino-Casino có bịp không

MS200 Type 1 Surge Protective Device

Model: MS200-240Y - Origin: CITEL / US
The MS Series is a high-performance UL 1449 Listed Type 1 SPD designed for critical panels located in the harshest environments. Imax 220kA per phase, Protects All Modes, Real-Time LED indicators, Audible Alarm, Remote Contacts, Smart Diagnostic Indicating Remaining Surge Capacity, All Enviromental Ratings Available, Optional Surge Counter and UL1283 Electromagnetic Interference Filter.. Detail

M50 Series Type 1 Surge Protective Device

Model: M50-277Y - Origin: CITEL / US
M50 Series: For AC 3-phase network: In : 20 kA, Imax : 50 kA/100kA, No leakage current, Visual indicator and audible Alarm, 2 formats :side or back nipple, UL 1449 4ed. certification. Detail

ATCOMPACT M1 30kA AC Surge Protection Panel

Model: AT-8161 - Origin: AT3W / Spain
Surge Protective Devices must be installed in parallel with the Low Voltage single phase power supply line-230Vac (L+N), Protection categories according to REBT I, II, III and IV. Impulse current  30kA(10/350µs), 65kA(8/20µs), Up<1500V, tr <25ns, Uc= 255Vac. Limits supply following currents. (Module: ATSHIELD 230M).. Detail

ATCOMPACT M2 15kA AC Surge Protection Panel

Model: AT-8117 - Origin: AT3W / Spain
Surge Protective Devices must be installed in parallel with the Low Voltage single phase power supply line-230Vac (L+N), Protection categories according to REBT I, II, III and IV. Impulse current  15kA(10/350µs), Up<700V, tr <25ns, Uc= 255Vac. Limits supply following currents. (Module: ATSUB-2P 15). Detail

ATCOMPACT T2 40kA AC Surge Protection Panel

Model: AT-8140 - Origin: AT3W / Spain
Surge Protective Devices must be installed in parallel with the Low Voltage 3 phase power supply line-230/400Vac, Protection Categories according to REBT: I, II, III and IV, Impulse current 40kA(8/20µs), Up<700V, tr <25ns, Uc= 255/440Vac. Limits supply following currents. (Module: ATSUB-4P 40)   . Detail

ATCOMPACT M2 40kA AC Surge Protection Panel

Model: AT-8139 - Origin: AT3W / Spain
Surge Protective Devices must be installed in parallel with the Low Voltage single phase power supply line-230Vac (L+N), Protection categories according to REBT: I, II, III and IV, 40kA(8/20µs), Up<700V, tr <25ns, Uc= 255Vac. Limits supply following currents. (Module: ATCOVER 230M) . Detail

ATCOMPACT T1 50kA AC Surge Protection Panel

Model: AT-8150 - Origin: AT3W / Spain
 ATCOMPACT protection boxes are made of several kind of SPD aiming the protection of all lines out 3P-230/400Vac. Protection categories according III,IV (REBT), Impulse current 50kA (10/350µs), Nominal discharge current 50kA (8/20µs), Up=4000V, tr<100ns, Uc=255/440Vac. ATCOMPACT are to be installed parallel with power line. Withstands direct lightning strike current. Limits supply following currents. (Module: 3xATSHOCK L + ATSHOCK N).. Detail
Including 8 product(s) in this category
Surge Protection for BTS

{关键字}

Surge Protection - Industrial sites

{关键字}

SPD Installation and Rules

{关键字}

Choosing Surge Protectors

{关键字}

Partners
  • {关键字}
  • {关键字}
  • {关键字}
  • {关键字}
  • {关键字}
Các game casino-Casino có bịp không