Home >
Các game casino-Casino có bịp khôngLightning protection > AC Surge Protectors
Các game casino-Casino có bịp khôngAC Surge ProtectorsType 1 AC Surge Protectors (21)Type 1 surge protectors are designed to be installed where a direct lightning strike risk is high, especially when the building is equipped with external lightning protection system (LPS or lightning rod ). In this situation, EN 61643-11 and IEC 61643-11 standards require the Class I test to be applied to surge protectors : this test is characterized by the injection of 10/350 μs impulse current in order to simulate the direct lightning strike consequence. Therefore these Type 1 AC surge protectors must be especially powerful to conduct this high energy impulse current. Các game casino-Casino có bịp khôngCITEL Type 2 DIN Rail AC Surge Protectors (18)CITEL surge protectors Type 2 & 3 are designed to be installed at the beginning of the installation, in the main switchboard, or close to sensitive terminals, on installations without LPS (lightning rods ). These protectors are tested following the Class II test from IEC61643-11 or EN61643-11standards and based on 8/20 μs impulse current injection. AT3W Type 2 DIN Rail AC Surge Protectors (6)AC Surge Protectors are designed to meet all your surge protection needs for any low voltage installation - single or three phase. DIN Rail, Type connection 2 & 3, Robust connectors. Easy to install. Các game casino-Casino có bịp khôngAC Power Surge Protector Panels (8)AC boxes surge protectors are devices for low voltage electrical installations 230/400V or 120/208V (Single or Three Phase). SPDs Type 1,2 or 3 for effective protection of sensitive equipment, in addition to the surge protector installation (coordination surge protector). Robust connectors, suitable for all type of connection. Các game casino-Casino có bịp khôngType of surge protectorsThe AC power surge protectors are split into 3 categories by IEC 61643-11 and EN 61643-11 standards, with the following 3 classes of tests. These different tests depend on the location of the surge protector in the AC network and on the external conditions. Type 1 surge protectorsType 1 surge protectors are designed to be installed where a direct lightning strike risk is high, especially when the building is equipped with external lightning protection system (LPS or lightning rod). In this situation, EN 61643-11 and IEC 61643-11 standards require the Class I test to be applied to surge protectors : this test is characterized by the injection of 10/350 μs impulse current in order to simulate the direct lightning strike consequence. Therefore these Type 1 surge protectors must be especially powerful to conduct this high energy impulse current. Type 2 surge protectorsType 2 surge protectors are designed to be installed at the entrance of the installation, in the main switchboard, or lose to sensitive terminals, on installations without LPS (lightning rods). These protectors are tested following the lass II test from IEC61643-11 or EN61643-11 standards and based on 8/20 μs impulse current injection. Type 3 surge protectorsIn case of very sensitive or remote equipment, secondary stage of surge protectors is required : these low energy PDs could be Type 2 or Type 3. Type 3 SPDs are tested with a combination waveform (1,2/50 μs - 8/20 μs) following Class III test |
|