Các game casino-Casino có bịp khôngCITEL surge protectors Type 2 & 3 are designed to be installed at the beginning of the installation, in the main switchboard, or close to sensitive terminals, on installations without LPS (lightning rods ). These protectors are tested following the Class II test from IEC61643-11 or EN61643-11standards and based on 8/20 μs impulse current injection. DS 74R Type 2 AC Multipolar 3-phase Surge Protector 70kA
Model: DS74R - Origin: CITEL / France
CITEL DS74R: Type 2 Multipolar Surge Protectors are designed to be installed at the origin of the Low Voltage system or close to sensitive equipment to protect against transient voltages coupled into the Low Voltage network. DS74R are to install parallel with with the low voltage supply line three phase lines 230/400 V 3-phase+N. Type protection L-G, N-G. Maximum discharge current max. withstand 8/20 μs Imax=70 kA. Up=1.4kV.. Detail
Các game casino-Casino có bịp khôngCITEL DS72R Type 2 AC Single-phase Multipolar Surge Protector 70kA
Model: DS72R - Origin: CITEL / France
CITEL DS72R: Type 2 Multipolar Surge Protectors are designed to be installed at the origin of the Low Voltage system or close to sensitive equipment to protect against transient voltages coupled into the Low Voltage network. DS72R are to install parallel with with the low voltage supply line single phase lines-230Vac. Type protection L-G, N-G. Maximum discharge current max. withstand 8/20 μs Imax=70 kA. Up=1.8kV, tr <25ns, Uc= 400Vac. . Detail
Các game casino-Casino có bịp khôngDAC50VG-31-275 Type 2 AC surge protector - 3-phase+N. VG
Model: DAC50VG-31-275 - Origin: CITEL / France
The pluggable surge protectors Type 2+3 DAC50VG, are designed to protect AC powerline at the main switchboard of the installation. Equipped with the exclusive CITEL’s VG technology, the range achieves an improved protection level and a total absence of leakage current, guaranteeing a maximum protection efficiency, a simplification of use (no additional SPD required) and a maximum lifetime. Detail
DS44VGS Type 2+3 Multi-Pole AC Surge Protector
Model: DS44VGS-230 - Origin: CITEL / France
CITEL DS44VGS Type 2+3 Multi-Pole AC Surge Protector are used for distribution panels of three-phase networks. They provide common-mode protection (between the active conductors and ground) and are available with an option remote alarm. DS44VGS allows a connection in parallel mode. Maximal discharge current max. withstand 160kA. Up=1.25kV, tr<25ns, Uc=255Vac (L-G/N).. Detail
DS44 3 phase AC surge protector
Model: DS44 - Origin: CITEL / France
DS44 surge protectors are used mainly for distribution panels of three-phase networks. They provide common-mode protection (between the active conductors and ground) and are available with an option remote alarm. DS44 allows a connection in parallel mode. Maximal discharge current max. withstand @ 8/20 μs 40kA. Up=1.55kV, tr<25ns, Uc=255Vac (L-G/N). Fixing DIN Rail. Limits supply following currents.. Detail
CITEL DS42 Type 2 AC 1 phase Surge Protector-40kA
Model: DS42 - Origin: CITEL / France
DS42 surge protectors are used mainly for distribution panels of 1-phase networks. They provide common-mode protection (between the active conductors and ground) and are available with an option remote alarm. DS42 allows a connection in parallel mode. Maximal discharge current max. withstand @ 8/20 μs 40kA. Up=1.25kV, tr<25ns, Uc=255Vac (L-G/N). Fixing DIN Rail. Limits supply following currents.. Detail
DS40VG Type 2+3 AC surge protector 2P (L+N)
Model: DS42VG-230 - Origin: CITEL / France
DS40VG Type 2 +3 AC surge protector, using CITEL's 'VG technology'. In : 20 kA, Imax total: 80 kA, Pluggable module, Follow and operating current : none, No ageing, Optional remote signaling state, Optimized to TOV, EN 61643-11, CEI 61643-11, UL1449 ed.4 compliance.. Detail
|
|