Các game casino-Casino có bịp khôngType 1 surge protectors are designed to be installed where a direct lightning strike risk is high, especially when the building is equipped with external lightning protection system (LPS or lightning rod ). In this situation, EN 61643-11 and IEC 61643-11 standards require the Class I test to be applied to surge protectors : this test is characterized by the injection of 10/350 μs impulse current in order to simulate the direct lightning strike consequence. Therefore these Type 1 AC surge protectors must be especially powerful to conduct this high energy impulse current. DS250E Series Type 1+2 Surge Protector
Model: DS250E - Origin: CITEL / France
CITEL DS250E AC power Surge Protective Devices (SPD) are designed to meet all your surge protection needs for any low voltage installation. DS250E are to install parallel with with the low voltage supply line single phase lines-230V (L/N). Type protection L-G, N-G. Withstands direct lightning strike current. Max. lightning current by pole max. withstand @ 10/350 μs Iimp 25 kA, Maximal discharge current max. withstand @ 8/20 μs 140kA. Up=2.5kV, tr <25ns, Uc= 330Vac. Internal disconnection, status indicator and remote signaling. Detail
DS154VG Heavy Duty Type 1 AC Surge Protector Device
Model: DS154VG-300 - Origin: CITEL / France
DS154VG AC surge protectors are designed to be connected in multi-pole configuration to protect single phase 230/400V 3-phase+N AC networks. They are sometimes associated with a dedicated N/PE SPD. DS154VG are to install parallel with with the low voltage. Max. lightning current max. withstand @ 10/350μs Iimp 60kA, Maximal discharge current max. withstand @ 8/20μs 160kA. Detail
ATSUB140-230 AC surge protection modules
Model: AT-8214 - Origin: AT3W / Spain
ATSUB 140-230 surge protective devices are to be installed in parallel with the low voltage supply line single phase lines-230V (L). Protection categoires according to REBT: I, II, III, VI. Impulse current 140kA(8/20µs) and 30kA(10/350µs), Up<900V, tr <25ns, Uc= 255Vac. Fixing DIN Rail. Limits supply following currents.. Detail
ATSUB 100 AC Line protection. Max current of 100kA
Model: AT-8256 - Origin: AT3W / Spain
ATSUB 100 surge protective devices are to be installed in parallel with the low voltage supply line single phase lines-230V (L). Protection categoires according to REBT: I, II, III, VI. Impulse current 100kA(8/20µs) and 25kA (10/350µs), Up = 1,3kV, tr <25ns, Uc= 275Vac. Fixing DIN Rail. Limits supply following currents.
. Detail
ATSUB 140 N Neutral protection -140kA
Model: AT-8218 - Origin: AT3W / Spain
ATSUB 140-N surge protective devices are to be installed in parallel with the low voltage supply line for Neutral protection lines (N). Protection categoires according to REBT: I, II, III, VI. Impulse current 140kA (8/20µs) and 30kA(10/350µs), Up<900V, tr
. Detail
ATSHIELD TT Protection of both line and neutra 400Vac three phase lines
Model: AT-8616 - Origin: AT3W / Spain
ATSHIELD TT (AT-8616) Surge Protective Devices combined technology against direct lighting strikes. ATSHIELD TT must be installed in parallel with the Low Voltage three phase power supply line-230/400Vac(3L+N), Protection Categories according to REBT: I, II, III and IV, Impulse current 30kA (10/350µs), 65kA (8/20µs), Up<1500V, tr<100ns, Uc=255/440Vac. Thermodynamic control device and light alarm for each phase. Fixing DIN Rail. Limits supply following currents.. Detail
ATSHOCK L Line-ground protection. 50kA
Model: AT-8350 - Origin: AT3W / Spain
ATSHOCK L Surge Protective Devices are to be installed parallel with the low voltage supply line, connected to Phase and Ground. Protection categories according to REBT: III & VI. ATSHOCK L provide protection even against direct lightning strikes. Impulse current 50kA (10/350µs). 50kA (8/20µs), Up<4kV, tr <100ns, Uc= 255Vac. Fixing DIN Rail. Limits supply following currents.. Detail
|
|